Table 1 Changes in Standard for the Energy-saving Design of domestic new buildings_U-values of building parts by region (Unit: W/㎡K)

Time of revision Wall Roof Floor Window
Central Southern Jeju Central Southern Jeju Central Southern Jeju Central Southern Jeju
Sep. 15, 1979 -Dec. 31, 1980 1.05 1.05 1.05 Double-glazed window
Jan. 1, 1981 -Mar. 26, 1984 0.58 0.58 1.16 3.49 or double-glazed window
Mar. 27, 1984 -Jul. 20, 1987 0.58 1.16 0.58 1.16 0.58 1.16 3.49 or double-glazed window
Jul. 21, 1987 - Jan. 16, 2001 0.58 0.76 1.16 0.41 0.52 0.76 0.58 0.76 1.16 3.37 3.60 5.81
Jan. 17, 2001 - Jul. 9, 2008 Direct 0.47 0.58 0.76 0.29 0.35 0.41 0.35 0.41 0.47 3.84 4.19 5.23
Ind. 0.64 0.81 1.10 0.41 0.52 0.58 0.52 0.58 0.64 5.47 6.05 7.56
Jul. 10, 2008 - Jan. 31, 2011 Direct 0.47 0.58 0.76 0.29 0.35 0.41 0.35 0.41 0.47 3.00(3.40) 3.30(3.80) 4.20(4.40)
Ind. 0.64 0.81 1.10 0.41 0.52 0.58 0.52 0.58 0.64 4.30(4.60) 4.70(5.30) 6.00(6.30)
Feb. 1, 2011- Sep. 30, 2013 Direct 0.36 0.45 0.58 0.20 0.24 0.29 0.30 0.35 0.35 2.10(2.40) 2.40(2.70) 3.10(3.40)
Ind. 0.49 0.63 0.85 0.29 0.34 0.41 0.43 0.50 0.50 2.80(3.20) 3.10(3.70) 3.70(4.30)
Oct. 1, 2013- Presenta) Direct 0.27 0.34 0.44 0.18 0.22 0.28 0.23 0.28 0.33 1.50(2.10) 1.80(2.40) 2.60(3.00)
Ind. 0.37 0.48 0.64 0.26 0.31 0.33 0.35 0.40 0.47 2.20(2.60) 2.50(3.10) 3.30(3.80)
a) From the 2008 Standard for Energy-saving Design, different standards of window were applied to MDU and buildings other than MDU. ( ) denotes a standard for buildings other than MDU.