Division | Unit | General MDU to which the Standard for Energy-saving Design by year was applied | Passive MDU |
2001 | 2008 | 2011 | 2013 |
Type of frame | mm | PVC 115mm | PVC 115mm | PVC 225mm | PVC 225mm | PVC 270mm |
Type of pane | mm | 16mm double-glazed(5CL+6Air+5CL) | 22mm double-glazed(5C+12Air+5CL) | 22mm double low-e glazing(5LE+12Ar+5CL)+ 6mm single glazing (6CL) | 22mm double low-e glazing(5LE+12Ar+5CL)+22mm double-glazed(5CL+12Air+5CL) | 22mm double low-e glazing(5LE+12Ar+5CL) + 39mm triple low-e glazing(6LE+12Ar+3CL+12Ar+6LE) |
Window construction cost | KRW 1000/household | 6,274 | 6,613 | 11,080 | 12,044 | 19,317 |
Air-tight tape construction cost | KRW 1000/household | - | - | - | - | 901 |
Type of door | | Ordinary fire door | Insulated fire door |
Door construction cost | KRW 1000/household | 3,003 | 3,003 | 3,003 | 3,003 | 4,125 |
Type of wall insulation | | Internal insulation | Internal insulation | Internal insulation | Internal insulation | Outside insulation |
Type of insulation | | Extrusion #1, density 30kg/m3, U-value 0.028 | Diverse insulation applied (see Table 2) |
Insulation thickness | mm | 65 | 65 | 85 | 120 | 115~225 |
Wall insulation construction cost | KRW 1000/household | 9,436 | 9,436 | 9,723 | 10,225 | 17,4341) |
Balcony thermal bridge breaker system construction cost | KRW 1000/household | - | - | - | - | 1,166 |
Type of ventilation system | | Air-supply and exhaust ventilation system | Heat recovery ventilation system |
Ventilation system construction cost2) | KRW 1000/household | 522 | 522 | 522 | 522 | 1,028 |
Type of boiler | | Individual gas boiler | Pallet boiler |
Boiler construction cost | KRW 1000/household | 791 | 791 | 791 | 791 | 1,487 |
Total (design cost) | KRW 1000/household | 20,028 | 20,367 | 25,120 | 26,586 | 45,460 |