Table 3 Major element technologies of the zero carbon green home

Division Contents Performance German passive house performance criterion
External insulation system Southern side EIFS (integrated structure-type, cellulose insulation) 0.15 W/m2・K 0.15 W/m2・K and below
Western side EIFS (ventilation structure)
Eastern side wet system 1(EPS board), wet system 2 (VIP vacuum insulated panel)
Northern side wet system 3 (PUR polyurethane rigid foam)
Window and door system High insulated and airtight window 0.89 W/m2・K 0.8 W/m2・K and below
Superadiabatic vacuum glazing window 0.83 W/m2・K
Superadiabatic vacuum glass door (1st floor door) 0.8 W/m2・K
Superadiabatic vacuum fire door (entrance hall and balcony door) 0.6 W/m2・K
Shading device External venetian blind (EVB) - -
Equipment system Waste heat recovery ventilator 85% heat recovery 85% heat recovery
Heating, ventilation, lighting control system - -
LED lighting - -
New and renewable energy supply system Wood pellet boiler 50 kW × 2 units -
Photovoltaic system (rooftop) 36 kW -